00/ENGINEERED FOR REALITY · INSIDE THE FENCELOGIC ENGINE
Precision at the
post-hole level.
A deep-dive into the algorithms that power FenceLogic. We don't just estimate — we engineer. Slope-corrected geometry, static load analysis, automated bracing logic, and BOMs accurate down to the crimp sleeve.
- · Static Load Calculation
- · Slope-Correction Logic
- · Multi-Tenant Architecture
- · BOM Granularity
- · API-First Infrastructure
- · Direct-to-Cart Integration
| SKU | Item | Unit | Qty | € / unit |
|---|---|---|---|---|
| FL-PST-CRN-2400 | End / corner post · 2.4 m · galvanized | ea | 12 | € 38.40 |
| FL-PST-LIN-1800 | Line post · 1.8 m · driven | ea | 82 | € 18.20 |
| FL-WIR-HT125 | High-tensile wire · 12.5 ga · class 3 | m | 3 414 | € 0.41 |
| FL-STR-INL | In-line strainer · ratcheted | ea | 16 | € 7.90 |
| FL-CRP-S25 | Crimp sleeve · 2.5 mm · sealed | ea | 212 | € 0.18 |
| FL-BRC-H-COR | H-brace assembly · corner kit | set | 4 | € 64.00 |
| FL-INS-COR | Insulator · corner · UV-stable | ea | 32 | € 1.10 |
| FL-CON-25KG | Concrete · 25 kg bag | bag | 48 | € 4.80 |
| FL-GTE-400 | Gate set · 4.0 m · double swing | set | 1 | € 412.00 |
| Subtotal · 9 line items | 487.2 m | € 14,820.40 | ||
01/HD SATELLITE · LiDAR · GIS
Plan directly on the property — with engineering-grade terrain data.
HD imagery + cadastral overlays
Plan with Google Maps HD or official GIS layers. Surveyed parcel boundaries are loaded automatically so customers stay inside their legal footprint.
Slope-correction logic
The engine calculates Real Path Length versus Horizontal Map Length. Steep gradients are flagged and the engine identifies exactly where stepped panels or racked sections are required.
LiDAR & DEM integration
Laser-scan elevation models and Mapbox elevation data drive automatic detection of low points (compression posts) and high points (deadman anchors).
Benefit
Never under-order wire for hilly terrain again.
L_real = L_horiz / cos(α) → +5.45% additional wire required
02/STRAIN & STATIC LOAD ANALYSIS
Engineered specifically for High-Tensile systems.
Cumulative pull calculation
The engine calculates the cumulative pull on every end-assembly based on wire gauge (e.g. 12.5 ga), strand count, and tension target. 113 kg per wire at standard HT spec is treated as a hard constraint, not a guideline.
Automated bracing logic
Based on the angle of direction change (Δθ > 10°), the engine automatically inserts H-Braces, N-Braces or Deadman anchors into the BOM and the visual plan — in the right orientation.
Soil & foundation calculator
Required embedment depth and concrete volume are calculated against soil class (rock, clay, sand) and frost-line depth.
Benefit
Brand-safe builds. The engine refuses to let your dealers ship a fence that will fail under tension.
Δθ > 10° → engine inserts H/N-brace · 12.5 ga × 8 strands = 113 kg / wire
03/BOM GRANULARITY
Accuracy down to the crimp sleeve.
While competitors stop at “posts and rolls,” FenceLogic calculates the minutiae — the parts that decide whether a build holds or fails.
IN-LINE STRAINERS
Auto-placed every 200–400 m on straight sections.
INSULATOR TYPES
Distinguishes corner, line and end insulators automatically.
HARDWARE COUNTS
Every nut, bolt, staple and brace pin accounted for.
CONCRETE VOLUME
Cubic meters or bag-count from hole depth × post diameter.
04/SAAS ARCHITECTURE
Built for manufacturers who run hundreds of dealers.
A multi-tenant control plane gives manufacturers full authority over catalog, pricing and engineering rules — while dealers and field crews work inside a tightly scoped, brand-safe planner.
Real path
487.20 m
Slope max
+8.4°
Posts · Strainers
94 · 4
BOM ready
€ 14,820.40
DEALER TERRITORY · EU-WEST · 38 ACTIVE PROJECTS
- MULTI-TENANT ARCHITECTURE
- Manage thousands of dealers from one master manufacturer account, with isolated data, branding and permissions per tenant.
- REGIONAL PRICING
- Override master pricing for specific territories, currencies or dealer tiers without forking the catalog.
- LEAD ROUTING
- Smart-assign leads generated by the configurator to the nearest authorized installer based on postal code or service radius.
- STYLE TEMPLATES
- Define complex rules per fence type — for example, dedicated post spacing for livestock vs. equine vs. game-exclusion fencing.
- CONSTRAINT CHECKING
- The engine refuses illegal configurations — for example, exceeding the maximum span between HT strainers — so your brand is never tied to a failing fence.
05 / GET STARTED
Ready to set the new industry standard?
Schedule a technical deep-dive with our engineering team to see the API and the backend rules engine in action — with your catalog and your territories.